Results for 'Nanoelectronics Electrical & Electronics Engineering Laser Electronic Engineering Micro-Electrical-Mechanical Systems Micro Systems Engineering Biosensors Nanowires Nanolithography Nano Biomaterial'

Order:
  1.  50
    Examining the Band Gap Structure of Nano-Electronic Devices, in Addition to Introducing a Method for Researching the Performance of One-Dimensional Systems.Afshin Rashid - 2024 - Elsevier Bv 9.
    based on organic materials can be mechanically exible to a large extent because of the loose intermolecular bonds in the nano-electrons created from them. Unlike these organic materials, minerals such as silicon, germanium, and gallium arsenide can be used in the structure of electronic devices only in crystalline states, and in this case, covalent bonds make exibility impossible in them. Makes. Properties such as strength, exibility, electrical conductivity, magnetic properties, color, reactivity, etc. Starting to change the properties (...)
    Download  
     
    Export citation  
     
    Bookmark  
  2.  48
    Nanoantennas Distribution of Alternating Current (With a Wavelength That Is 100 Times Smaller Than the Wavelength of Free Space).Afshin Rashid - 2024 - Elsevier Bv 15.
    Note: In general, in order to receive the electromagnetic wave in the space, the dimensions of the antenna must be in the order of the wavelength of the input to its surface. Due to the very small dimensions of nano sensors, nano antennas need to have a very high working frequency to be usable. -/- The use of graphene helps to solve this problem to a great extent. The speed of propagation of waves in CNTs and GNRs can (...)
    Download  
     
    Export citation  
     
    Bookmark  
  3.  45
    Signal Measurement Electrochemical Methods are very Suitable for Detecting Direct DNA Oxidation because Electrochemical Reactions Directly Generate Electronic Signals.Afshin Rashid - 2024 - Elsevier.
    Signal measurement Electrochemical methods are very suitable for detecting direct DNA oxidation because electrochemical reactions directly generate electronic signals and therefore do not require expensive converters. In addition, in this process, because the order of the immobilized game can be limited to onlya series of electrode substrates, the act of tracking is performed by a series of in expensive electrochemical analyzes. Electrochemical sensors are used to perform clinical or environmental tests; The basis of the sensitivity of electrochemical signals to (...)
    Download  
     
    Export citation  
     
    Bookmark